Serverdex · explainer
MCP transports: stdio, SSE and Streamable HTTP
Serverdex live check, 26 Nov 2026 (13,381 answering remotes). The ecosystem has consolidated on 2025-06-18 — the Streamable HTTP era. Only 309 still speak 2024-11-05 (the HTTP+SSE era), and just 10 have adopted the newest 2026-07-28. Separately, 227 listed remotes publish only the deprecated SSE transport and are not callable by a Streamable-HTTP client.
The three transports
- What it is
- stdioNewline-delimited JSON-RPC over a subprocess's stdin/stdout
- Streamable HTTPOne HTTP endpoint: POST requests, replies as JSON or an SSE stream
- HTTP+SSE (legacy)Separate SSE + POST endpoints; the pre-2025-03-26 remote transport
- Where it runs
- stdioLocal: the client launches the server on the same machine
- Streamable HTTPRemote: a hosted server over the network
- HTTP+SSE (legacy)Remote (old clients/servers only)
- Introduced
- stdioFrom the first revision
- Streamable HTTPProtocol 2025-03-26
- HTTP+SSE (legacy)Protocol 2024-11-05
- Status
- stdioStandard
- Streamable HTTPStandard; the one to use for remote
- HTTP+SSE (legacy)Deprecated — backwards compatibility only
- Auth
- stdioInherited from the local process
- Streamable HTTPBearer tokens, API keys, custom headers; OAuth recommended
- HTTP+SSE (legacy)As HTTP+SSE allowed
- When to use
- stdioA server on your own machine
- Streamable HTTPAnything hosted or shared
- HTTP+SSE (legacy)Only to talk to a server built on 2024-11-05
1. Two standard transports today
The current MCP specification revision is 2026-07-28, and its architecture page is blunt about the options: “MCP supports two transport mechanisms,” stdio and Streamable HTTP. The 2025-03-26 spec, which introduced the current remote transport, puts it the same way: “The protocol currently defines two standard transport mechanisms for client-server communication.” There is no third standard transport — SSE on its own is the old one, kept only for compatibility.
Both carry the same JSON-RPC 2.0 messages; the transport is only how the bytes move. So the choice is purely about where the server runs: on your machine, or across a network.
2. stdio — the local transport
With stdio, “the client launches the MCP server as a subprocess.” The server “reads JSON-RPC messages from its standard input (stdin) and sends messages to its standard output (stdout)”; messages “are delimited by newlines, and MUST NOT contain embedded newlines.” It is for “local processes on the same machine,” with no network in between, and the spec says “clients SHOULD support stdio whenever possible.”
This is what a desktop client like Claude Desktop uses when you add a server by command — npx or uvx launches it and the two talk over the process's pipes. Nothing is exposed to the network.
3. Streamable HTTP — the remote transport, and what it replaced
Streamable HTTP is for servers reached over the network. The server “MUST provide a single HTTP endpoint path” that “supports both POST and GET methods”; the client sends each message as an HTTP POST, and the server “can optionally make use of Server-Sent Events (SSE) to stream multiple server messages.” A hosted server at, say, https://example.com/mcp speaks this transport.
It arrived in protocol revision 2025-03-26, and that page states plainly that it “replaces the HTTP+SSE transport from protocol version 2024-11-05.” The old transport used a separate long-lived SSE channel plus POSTs; it is now “deprecated” and supported only for backwards compatibility. New servers should expose Streamable HTTP.
Because it is on the network, the spec attaches security requirements: servers “MUST validate the Origin header on all incoming connections to prevent DNS rebinding attacks,” local servers “SHOULD bind only to localhost,” and servers “SHOULD implement proper authentication” — bearer tokens, API keys or custom headers, with OAuth recommended.
4. What the fleet actually runs
The Serverdex live check reaches every listed remote server over Streamable HTTP. On 26 November 2026, of 13,381 answering servers the great majority spoke protocol 2025-06-18, with 2,639 on 2025-03-26 and only 309 still on 2024-11-05, the HTTP+SSE era. Just 10 had moved to the newest 2026-07-28 — new spec revisions take months to reach the fleet. Another 227 listed remotes publish only the deprecated standalone SSE transport, so a modern Streamable-HTTP client cannot call them at all.
The practical reading: build remote servers on Streamable HTTP, keep SSE only if you must serve old clients, and expect the newest protocol revision to be rare for a while after it ships.
5. The decision rule
Pick by where the server runs, not by preference.
- A server on your own machine, launched by the client: stdio.
- A hosted or shared server over the network: Streamable HTTP, with Origin validation and auth.
- Standalone HTTP+SSE: only to stay compatible with a client or server built on protocol 2024-11-05 — never for new work.
Where this shows up on Serverdex
46,066 MCP servers from the official registry are listed here, each with a daily credential-free live check, the tool list it exposes and the estimated token cost of its definitions — the numbers this comparison turns on.
- Remote MCP servers answering now — every listed Streamable-HTTP server with its live-check result
- MCP server health check — run the handshake against a server and see its transport and protocol version
- MCP client compatibility — which clients support which transports
- MCP config generator — write the stdio or remote config for your client
Questions
- What transports does MCP support?
- Two standard transports: stdio, for a local server the client launches as a subprocess and talks to over stdin/stdout, and Streamable HTTP, for a remote server over a single HTTP endpoint with optional SSE streaming. The older standalone HTTP+SSE transport was replaced by Streamable HTTP in protocol revision 2025-03-26 and is kept only for backwards compatibility.
- Is SSE deprecated in MCP?
- The standalone HTTP+SSE transport from protocol 2024-11-05 is deprecated — the 2025-03-26 spec says Streamable HTTP “replaces the HTTP+SSE transport.” SSE itself is not gone: Streamable HTTP still uses Server-Sent Events to stream replies from its single endpoint. It is the old two-endpoint SSE transport that is legacy.
- stdio or Streamable HTTP — which should I use?
- Use stdio when the server runs on the same machine as the client; it is launched as a subprocess with no network exposure, and the spec recommends supporting it whenever possible. Use Streamable HTTP when the server is hosted and reached over the network, and apply its security requirements: validate the Origin header and authenticate connections.
Sources (read 26 November 2026)
- MCP architecture — “MCP supports two transport mechanisms” (stdio, Streamable HTTP)
- MCP specification (latest, revision 2026-07-28)
- MCP 2026-07-28 — Transports overview
- MCP 2025-03-26 — Transports (introduces Streamable HTTP; replaces HTTP+SSE; security)
Not claimed here because it could not be read from a primary source on 26 November 2026: The fine-grained Streamable HTTP rules (single endpoint, POST/GET, the Origin/localhost/auth security warning, session management) are quoted from the 2025-03-26 revision that introduced the transport; the 2026-07-28 sub-page was not fetched line by line, though its overview confirms the same two-transport model. Session-handshake details changed in 2026-07-28 and are not quoted here.; The protocol-version counts (309 / 2,639 / 10,358, plus 227 SSE-only) are Serverdex's own live scan on 26 Nov 2026, not an external figure..
More explainers: MCP vs CLI tools · MCP vs function calling · MCP vs RAG · MCP vs API · MCP vs OpenAPI · MCP vs A2A · MCP vs Agent Skills · MCP vs ACP · MCP vs connectors · MCP vs MCP gateways.